Sampling System – BLA2
BLA2 – System Purge Type
Features
- Sampling from low pressure devices or process lines:0-145 psig (0-10 bar)
- System purge
Basic Configuration
| Wetted Material | 316 SS |
| Sleeve Assembly | 250 ml sleeve with bottle retaining clip |
| Needle Assembly | Process/vent needle ID: 1.4 mm (0.06″) |
| Sampling Valve | BF Series 3-way ball valves: PTFE seat and FKM O-ring Max working pressure: 1500 psig @ 70℉ (103 bar @ 20℃) Temperature range: 0℉ to 450℉ (-18℃ to 232℃) |
| Connections | 1/4″ tube fitting |
Typical Installation Mode

1- Preparation
Place a new septum on the sample bottle. Insert the bottle with cap and septum into the sleeve until the septum is pierced by the needles. Swing down the bottle retaining clip.
2 – System Purge
Turn the handle to the “BYPASS” position, allowing the sample to flow continuously through the system and purge system to ensure representative sampling.
3 – Sampling
Turn the handle to “SAMPLE” position, allowing the sample to flow into the bottle. When the required amount has been taken, turn the handle to the “OFF” position to close the sampling system.
4- Off
Remove the bottle retaining clip and take out the bottle from the sleeve. The septum reseals automatically to complete the sampling process.
NVFCL-FITOK Valves & Twin Ferrule Fittings